| 电力避雷器的涉及的几个指标 |
| 添加时间:2019/2/15 14:30:55 浏览次数: |
| (1)伏秒特性:指电压与时间的对应关系。 (1) Volt-second characteristics: refers to the corresponding relationship between voltage and time. (2)工频续流:指雷电压或过电压放电结束,但工频电压仍作用在避雷器上,使其流过的工频短路接地电流。 (2) Power Frequency Continuous Current: refers to the end of lightning voltage or over-voltage discharge, but the power frequency voltage still acts on the arrester to make it flow through the power frequency short-circuit grounding current. (3)绝缘强度自恢复能力:电气设备绝缘强度与时间的关系,即恢复到原来绝缘强度的快慢。 (3) Self-restoring ability of insulation strength: the relationship between the insulation strength of electrical equipment and time, that is, the speed of restoring the original insulation strength. (4)避雷器的额定电压:把工频续流第一次过零后, 间隙所能承受的,不至于引起电弧重燃的最大工频电压,又称电弧电压。 (4) Surge arrester rated voltage: the maximum power frequency voltage, also known as arc voltage,xingtai.37ix.com.cnhengshui.37ix.com.cndingzhou.37ix.com.cntangshan.37ix.com.cncheng de.37ix.com.cnlangfang.37ix.com.cn which can be withstood by the gap after the first zero of power frequency continuous current, will not cause arc reburning. |
| 上一页 如何测量金属氧化物避雷器的工频参考电压? |